 When using the mSupply ColdChain application for the first time, the Sensor Settings screen will have two sections: When using the mSupply ColdChain application for the first time, the Sensor Settings screen will have two sections:
   *Options   *Options
-  *Found Sensors +  *Found Sensors 
 +<WRAP center round important 60%> Please refer to the [[en:cold_chain:getting_started|mSupply ColdChain Getting Started]] for information about the device settings and sensor requirements and recommendations when setting up the application for the first time. </WRAP>
  
 === Options === === Options ===
-**Logging interval:** Sets the default number of minutes between logs on sensors. Using the slider, you can set the default log interval to any length between 1 and 100 minutes. The logging interval applies for all sensors when they are first linked to the mSupply ColdChain application. Different log intervals can be set for each sensor in **''Available Sensors/Log interval.''**+**Logging interval:** Sets the default number of minutes between logs on sensors. Using the slider, you can set the default log interval to any length between 1 and 100 minutes. The logging interval applies for all sensors when they are first linked to the mSupply ColdChain application. Different log intervals can be set for each sensor in **Available Sensors/Log interval** (see below).
 {{ :en:cold_chain:pasted:20210215-215500.png?300 }} {{ :en:cold_chain:pasted:20210215-215500.png?300 }}
  
Line 32: Line 33:
 {{ :en:cold_chain:pasted:20210215-215831.png }} {{ :en:cold_chain:pasted:20210215-215831.png }}
  
-<WRAP center round tip 30%>We recommend you avoid the use special characters (e.g. -, +, *) in the sensor name. </WRAP>+<WRAP center round tip 50%>We recommend you avoid the use special characters (e.g. -, +, *) in the sensor name. </WRAP>
  
  
Line 39: Line 40:
  
  
-<WRAP center round important 30%> We recommend that each device should be linked to a maximum of six sensors. Each sensor should only be linked to one device. </WRAP>  
  
 ==== Temperature breach settings ==== ==== Temperature breach settings ====
Line 46: Line 46:
   ***Cumulative Exposure:** the sum of time the temperature is outside the specified range during a period.   ***Cumulative Exposure:** the sum of time the temperature is outside the specified range during a period.
 Temperature breach settings apply to all sensors.  Temperature breach settings apply to all sensors.
 +{{ :en:cold_chain:pasted:20210215-224848.png?250 }}
  
 === Single exposure breach configurations === === Single exposure breach configurations ===
Line 55: Line 55:
   *Cold breach   *Cold breach
 However, you can enter a custom name for each temperature breach category if required.  However, you can enter a custom name for each temperature breach category if required. 
- +{{ :en:cold_chain:pasted:20210215-224931.png?350 }} 
-<WRAP center round tip 30%>We recommend you avoid the use special characters (e.g. -, +, *) when naming breach categories. </WRAP>+<WRAP center round tip 50%>We recommend you avoid the use special characters (e.g. -, +, *) when naming breach categories. </WRAP>
  
 **Duration:** Using the slider, you can determine how long the temperature must continuously remain outside of the required temperature range for it to be considered a breach. You can set the duration to any length between 1 and 600 minutes. **Duration:** Using the slider, you can determine how long the temperature must continuously remain outside of the required temperature range for it to be considered a breach. You can set the duration to any length between 1 and 600 minutes.
-  +{{ :en:cold_chain:pasted:20210215-225005.png }}  
-The duration should be equal or greater to the log interval. The duration should also be a multiple of the log interval to ensure breaches are captured accurately.+<WRAP center round important 50%>The duration should be equal or greater to the log interval. The duration should also be a multiple of the log interval to ensure breaches are captured accurately.</WRAP>
  
 **Temperature:** Using the slider, you can set the temperature outside of which will result in a breach: **Temperature:** Using the slider, you can set the temperature outside of which will result in a breach:
   *below which will be a breach for the cold breach category, and    *below which will be a breach for the cold breach category, and 
   *above which will be a breach for the hot breach category.    *above which will be a breach for the hot breach category. 
 +{{ :en:cold_chain:pasted:20210215-225039.png }}
 The temperature selected can be between -30 and +50 degrees Celsius.  The temperature selected can be between -30 and +50 degrees Celsius.
  
Line 74: Line 75:
   *Hot cumulative   *Hot cumulative
   *Cold cumulative   *Cold cumulative
-You can enter a name for each temperature breach category.  +You can enter a name for each temperature breach category. 
-<WRAP center round tip 30%>We recommend you avoid the use special characters (e.g. -, +, *) when naming breach categories. </WRAP>+{{ :en:cold_chain:pasted:20210215-225113.png?350 }}  
 +<WRAP center round tip 50%>We recommend you avoid the use special characters (e.g. -, +, *) when naming breach categories. </WRAP>
  
 **Duration:** Using the slider, you can determine the total time (sum) the temperature must remain outside of the required temperature range for it to be considered a cumulative breach. You can set the duration to any length between 1 and 600 minutes. **Duration:** Using the slider, you can determine the total time (sum) the temperature must remain outside of the required temperature range for it to be considered a cumulative breach. You can set the duration to any length between 1 and 600 minutes.
 +{{ :en:cold_chain:pasted:20210215-225159.png }}
 **Temperature:** Using the slider, you can set the temperature outside of which will result in a breach: **Temperature:** Using the slider, you can set the temperature outside of which will result in a breach:
   *below which will be a breach for the cold breach category, and    *below which will be a breach for the cold breach category, and 
   *above which will be a breach for the hot breach category.    *above which will be a breach for the hot breach category. 
 The temperature selected can be between -30 and +50 degrees Celsius.  The temperature selected can be between -30 and +50 degrees Celsius.
 +{{ :en:cold_chain:pasted:20210215-225226.png }}
 **Period:** The time period used for cumulative temperature configuration (and hence alerts) on the Sensor tab is set at 72 hours. **Period:** The time period used for cumulative temperature configuration (and hence alerts) on the Sensor tab is set at 72 hours.
  
-To view cumulative temperature breaches for a different period, you can change the time period on the Sensor Detail screen. The mSupply ColdChain application will use this time period to calculate cumulative temperature and display any breaches at the top of the Sensor Detail screen. +To view cumulative temperature breaches for a different period, you can [[en:cold_chain:sensors#sensor_detail|change the time period on the Sensor Detail screen]]. The mSupply ColdChain application will use this time period to calculate cumulative temperature and display any breaches at the top of the Sensor Detail screen.
- +
-<WRAP center round info 60%> You can export the sensor logs for further information and investigation regarding temperature breaches. </WRAP> +
- +
  
 +<wrap center round info 95%> You can export the sensor logs for further information and investigation regarding temperature breaches. </wrap>
 +\\
 +\\