| ===== Settings ===== | ===== Settings ===== | ||
| + | Selecting the Settings tab at the bottom right of the screen will take you to the Settings screen. From here, you can adjust the settings to: | ||
| + | *Sensors | ||
| + | *Temperature breach settings | ||
| + | {{ : | ||
| + | |||
| + | ==== Sensor settings ==== | ||
| + | When using the mSupply ColdChain application for the first time, the Sensor Settings screen will have two sections: | ||
| + | *Options | ||
| + | *Found Sensors | ||
| + | <WRAP center round important 60%> Please refer to the [[en: | ||
| + | |||
| + | === Options === | ||
| + | **Logging interval:** Sets the default number of minutes between logs on sensors. Using the slider, you can set the default log interval to any length between 1 and 100 minutes. The logging interval applies for all sensors when they are first linked to the mSupply ColdChain application. Different log intervals can be set for each sensor in **Available Sensors/Log interval** (see below). | ||
| + | {{ : | ||
| + | |||
| + | |||
| + | === Found sensors === | ||
| + | Any new sensors, not yet paired, will appear below this title. You can open new sensors by double-tapping anywhere on the sensor name/row. | ||
| + | |||
| + | **Blink:** Pressing the blink button will cause the sensor light to flash. You can use this feature to ensure that you are connecting to the correct sensor. \\ | ||
| + | ** Start logging from:** Using the date/time options, you can set the schedule for the first log. The sensor can be configured to start a maximum of 30 days from the link date. When you select '' | ||
| + | {{ : | ||
| + | |||
| + | === Available sensors === | ||
| + | Once a sensor has been linked to the mSupply ColdChain application, | ||
| + | {{ : | ||
| + | |||
| + | **Blink:** Pressing here will cause the sensor light to flash. You can use this feature to ensure that you are working with the correct sensor. \\ | ||
| + | **Download: | ||
| + | **Sensor Details:** This provides the MAC address for the sensor (this is found on the back of the sensor). The current battery level will also be displayed as a percentage. Neither field can be edited.\\ | ||
| + | **Sensor name:** Double-tap on sensor name/row or select the > in the row to enter a new name for the sensor. This is the name that will appear on the Sensors tab. You should choose a name to make it easy to identify. | ||
| + | {{ : | ||
| + | |||
| + | <WRAP center round tip 50%>We recommend you avoid the use special characters (e.g. -, +, *) in the sensor name. </ | ||
| + | |||
| + | |||
| + | **Log interval:** The log interval will initially be set to the default log interval. Using the slider, you can change the interval between logs to any length between 1 and 30 minutes. When you press '' | ||
| + | {{ : | ||
| + | |||
| + | |||
| + | |||
| + | ==== Temperature breach settings ==== | ||
| + | There are two breach categories: | ||
| + | ***Single Exposure:** any continuous period of time the temperature is outside the specified range. | ||
| + | ***Cumulative Exposure:** the sum of time the temperature is outside the specified range during a period. | ||
| + | Temperature breach settings apply to all sensors. | ||
| + | {{ : | ||
| + | |||
| + | === Single exposure breach configurations === | ||
| + | You should set a minimum temperature (cold breach) and maximum temperature (hot breach) for the single exposure breaches. The current setting will be displayed in the row for each category. | ||
| + | |||
| + | **Description: | ||
| + | *Hot breach | ||
| + | *Cold breach | ||
| + | However, you can enter a custom name for each temperature breach category if required. | ||
| + | {{ : | ||
| + | <WRAP center round tip 50%>We recommend you avoid the use special characters (e.g. -, +, *) when naming breach categories. </ | ||
| + | |||
| + | **Duration: | ||
| + | {{ : | ||
| + | <WRAP center round important 50%>The duration should be equal or greater to the log interval. The duration should also be a multiple of the log interval to ensure breaches are captured accurately.</ | ||
| + | |||
| + | **Temperature: | ||
| + | *below which will be a breach for the cold breach category, and | ||
| + | *above which will be a breach for the hot breach category. | ||
| + | {{ : | ||
| + | The temperature selected can be between -30 and +50 degrees Celsius. | ||
| + | |||
| + | |||
| + | === Cumulative Exposure Configurations === | ||
| + | You should set a minimum temperature (cold breach) and maximum temperature (hot breach) for the cumulative exposure configuration. The current setting will be displayed in the row for each category. | ||
| + | |||
| + | **Description: | ||
| + | *Hot cumulative | ||
| + | *Cold cumulative | ||
| + | You can enter a name for each temperature breach category. | ||
| + | {{ : | ||
| + | <WRAP center round tip 50%>We recommend you avoid the use special characters (e.g. -, +, *) when naming breach categories. </ | ||
| + | |||
| + | **Duration: | ||
| + | {{ : | ||
| + | **Temperature: | ||
| + | *below which will be a breach for the cold breach category, and | ||
| + | *above which will be a breach for the hot breach category. | ||
| + | The temperature selected can be between -30 and +50 degrees Celsius. | ||
| + | {{ : | ||
| + | **Period:** The time period used for cumulative temperature configuration (and hence alerts) on the Sensor tab is set at 72 hours. | ||
| + | |||
| + | To view cumulative temperature breaches for a different period, you can [[en: | ||
| + | |||
| + | <wrap center round info 95%> You can export the sensor logs for further information and investigation regarding temperature breaches. </ | ||
| + | \\ | ||
| + | \\ | ||
| + | | // Previous: | ||